Thermocouple & RTD Cables

Full Range of extension and compensating cables available.

 

Which insulation Material
Usable temperature range
Application Notes
PVC
-10C to 105C
Good general purpose insulation for "light" environments. Waterproof and very flexible.
PTFE
-75C to 250/300C
Resistant to oils, acids, other adverse agents and fluids. Good mechanical strength and flexibility.

Glass fibre

(Varnished)

-60C to 350/400C
Good temperature range but will not prevent ingress of fluids. Fairly flexible but does not provide good mechanical protection.
High temperature glass fibre
-60C to 700C
Will withstand temperature up to 700C but will not prevent ingress of fluids. Fairly flexible, not good protection against physical disturbance.
Ceramic Fibre
0C to 1000C
Will withstand high temperature, up to 1000ฐC. Will not protect against fluids or physical disturbance.

Glass fibre

(Varnished)

Stainless steel over braid

-60C to 350/400C
Good resistance to physical disturbance and high temperature (up to 400C ) Will not prevent ingress of fluids.

 

©Industrial Temperature Sensors Ltd.      

Ph.00353-45-898164     Fax.00353-45-896521