The VR-71 data logger
measures and records voltage signals within a measurement range of DC(±)15V.
It can record signals of 1-5V / 4-20mA as welll as output signals from a variety
of sensors.The most impressive feature is the software function that allows you
to create your own dot matrix patterns for unit display and then change the
recorded voltage signal into the desired unit and display accordingly to match
your measurings.
|
VR-71
|
![]() |
| 1.Input
Cable Jack(ch1/ch2) 2.Power Switch 3. DISPLAY Button 4.INTERVAL Button 5.REC/STOP Button 6.LCD Display 7. Communication Cable Jack 8. Stereo Mini Jack(φ2.5) 9.Clip |
|
Measure and Record with 2 Channels on 1 Unit
|
|
It is possible to measure and record on two channels with 1
unit. These two channels make it possible to obtain reliable
readings when measuring two related phenomena. By pressing the
DISPLAY button, you can choose to set the LCD display to show
both channels' readings alternatively, show one channel as a
fixed display or show neither channel.
|
|
Choose the Display Unit
|
|
Of course you can display the voltage
reading as is, or by using the software to select the desired
scale, convert and display the readings in the unit of your
choice.
|
|
Unit Display
|
|
It is possible using the software to create
and edit dot matrix patterns to be used in the LCD as the unit
of measurement.
![]() |
| Select from 20 Recording Intervals / Shortest at 0.02 seconds |
| Recording interval can be selected from 20 choices ( 0.02sec to 60 min ). Tere are also two Recording Modes to choose from : One-time or Endless. |
| Data Capacity : 8000 Readings x 2 Channels |
|
Each channel can record up to 8000 readings. At a recording
interval of 60 min, ( the longest possible recording interval )
that gives you one year of continuous recording capability.
|
|
|
VR-71
|
|
Number of Channels
|
2 (Common ground)
|
|
Measurement Item
|
Voltage
|
|
Measurement Range
|
Range ±1,2,6,15V
Auto Range:Fixed Range |
|
Measurement Accuracy
|
±0.5% ±5 dgt.
|
|
Display Resolution
|
Min 1mV
|
|
Recording Interval
|
20 selections : 0.02sec - 60min (Default : 10seconds)
|
|
Recording Capacity
|
8,000 Readings x 2 Channels
|
|
Recording Mode
|
Endless / One-time (Default : One-time)
|
|
LCD Display Items
|
Measurement Reading / Recording Status / Time / Memory
Capacity
|
|
Power Source
|
Battery Life Warning / Unit of Measurement /
2 AAA Alkaline Batteries LR03 |
|
Battery Life
|
About 5-9 months *1
|
|
Interface
|
Serial Communication (RS-232C)
|
|
Dimentions
|
H55×W88×D24
|
|
Weight
|
About 93g (including 2 batteries)
|
|
Temperature and Humidity
Durability of the Unit |
Temp: 0-50'C
Humidity: 90% RH or less no condensation |
|
Waterproof
|
None
|
|
Attached Sensor / Cable
|
2 Input Cables (VR-7101)
|
|
Other
|
It is possible to measure electrical current byVR-7103
*2
|
|
Compatible OS
|
Windows 98SE / Me / 2000 / XP
|
|
*1: At recording interval of 1 sec: about
5 months / at rec. interval of more than 2 seconds: 9 months at
a recording interval of 0.02 seconds: about 13 days.
|
|
|
*2:VR-7103 <4-20mA Probe>
Maximum Current Input : MAX 40mA Internal Resistance : 100Ω Output : 2V at 20mA / 0.4V at 4mA Conversion Accuracy : 0.5% Cable Length : 60 in (1.0m) |
![]() |
![]() |
|
Standard Kit for VR-71
|
![]() |
|
©Industrial Temperature Sensors Ltd. |
Ph.00353-45-408164 Fax.00353-45-408165 |