Menu
Your Cart

5331A

5331A
5331A
  • SKU: 5331A
  • Label: 5331A

5331A 2-wire programmable transmitter

Application

  • Linearized temperature measurement with Pt100...Pt1000, Ni100...Ni1000, or TC sensor.
  • Conversion of linear resistance variation to a standard analog current signal, for instance from valves or Ohmic level sensors.
  • Amplification of a bipolar mV signal to a standard 4...20 mA current signal.

Technical characteristics

  • Within a few seconds the user can program PR5331A to measure temperatures within all ranges defined by the norms.
  • The RTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.
  • Continuous check of vital stored data for safety reasons.

Mounting / installation

  • For DIN form B sensor head or DIN rail mounting with the PR fitting type 8421.

Download Datasheet

Environmental Conditions

Operating temperature

-40°C to +85°C

Calibration temperature

20...28°C

Relative humidity

< 95% RH (non-cond.)

Protection degree (encl./terminal)

IP68 / IP00

Mechanical specifications

Dimensions

Ø 44 x 20.2 mm

Weight approx.

50 g

Wire size

1 x 1.5 mm2 stranded wire

Screw terminal torque

0.4 Nm

Vibration

IEC 60068-2-6

2...25 Hz

±1.6 mm

25...100 Hz

±4 g

Common specifications

Supply

Supply voltage

7.2...35 VDC

Internal power dissipation

25 mW…0.8 W

Isolation voltage

Isolation voltage, test / working

1.5 kVAC / 50 VAC

Response time

Response time (programmable)

1...60 s

Voltage drop

7.2 VDC

Warm-up time

5 min.

Power on to stable output

4.5 s

Programming

Loop Link

Signal / noise ratio

Min. 60 dB

EEprom error check

< 3.5 s

Accuracy

Better than 0.05% of selected range

Signal dynamics, input

20 bit

Signal dynamics, output

16 bit

Effect of supply voltage change

< 0.005% of span / VDC

EMC immunity influence

< ±0.5% of span

Extended EMC immunity: NAMUR NE21, A criterion, burst

< ±1% of span

Input specifications

Common input specifications

Max. offset

50% of selected max. value

RTD input

RTD type

Pt100, Ni100, lin. R

Cable resistance per wire

5 Ω (max.)

Sensor current

Nom. 0.2 mA

Effect of sensor cable resistance (3-/4-wire)

< 0.002 Ω / Ω

Sensor error detection

Yes

Linear resistance input

Linear resistance min....max.

0 Ω...5000 Ω

TC input

Thermocouple type

B, E, J, K, L, N, R, S, T, U, W3, W5, LR

Cold junction compensation (CJC)

< ±1.0°C

Sensor error detection

Yes

Sensor error current: When detecting / else

Nom. 33 μA / 0 μA

Voltage input

Measurement range

-12...800 mV

Min. measurement range (span)

5 mV

Input resistance

10 MΩ

Output specifications

Current output

Signal range

4…20 mA

Min. signal range

16 mA

Load (@ current output)

≤ (Vsupply - 7.2) / 0.023 [Ω]

Load stability

≤ 0.01% of span / 100 Ω

Sensor error indication

Programmable 3.5…23 mA

NAMUR NE43 Upscale/Downscale

23 mA / 3.5 mA

Common output specifications

Updating time

440 ms

of span

= of the presently selected range

I.S. / Ex marking

ATEX

II 3 G Ex nA [ic] IIC T6...T4 Gc, II 3 G Ex ec [ic] IIC T6...T4 Gc, II 3 G Ex ic IIC T6...T4 Gc, II 3 D Ex ic IIIC Dc

IECEx

Ex nA [ic] IIC T6…T4 Gc, Ex ec [ic] IIC T6…T4 Gc, Ex ic IIC T6…T4 Gc, Ex ic IIIC Dc

CSA

Cl. I, Div. 2, Gp. A, B, C, D T6...T4, Ex nA[ic] IIC T6…T4 Gc

INMETRO

Ex nA [ic] IIC T6...T4 Gc, Ex ic IIC T6...T4 Gc, Ex ic IIIC Dc

Observed authority requirements

EMC

2014/30/EU & UK SI 2016/1091

ATEX

2014/34/EU & UK SI 2016/1107

RoHS

2011/65/EU & UK SI 2012/3032

EAC

TR-CU 020/2011

EAC Ex

TR-CU 012/2011

Approvals

ATEX

DEKRA 20ATEX0096X

IECEx

DEK 20.0059X

CSA

1125003

INMETRO

DEKRA 16.0013 X

DNV Marine

TAA0000101

EAC Ex

RU C-DK.HA65.B.00355/19