Performance characteristics
Pt100 accuracy class (EN 60751)
- A (± 0.15 °C at 0 °C)
- ± (0.15 + 0.002 × t)°C
- 1/3 B (± 0.1 °C at 0 °C)
- ± 1/3 × (0.3 + 0.005 × t)°C
- 1/10 B (± 0.03 °C at 0 °C)
- ± 1/10 × (0.3 + 0.005 × t)°C
Pt1000 accuracy class (EN 60751)
- A (± 0.15 °C at 0 °C)
- ± (0.15 + 0.002 × t)°C
- 1/3 B (± 0.1 °C at 0 °C)
- ± 1/3 × (0.3 + 0.005 × t)°C
Thermal response time, T50
- ≤ 1.5 s , Ø3 mm
- ≤ 6.1 s , Ø6 mm
- ≤ 7.6 s , Ø8 mm
Operating Temperature
- Standard -70C + 250C
- High Temperature 600C
- Cryo -196C + 250C
Sensor Diameter
- Standard 6mm
- Options 3mm or 8mm
Sensor length
- Configurable
Sensor tube material
- AISI 316L (1.4404)
Surface roughness wetted parts
- Ra ≤ 0.8 µm
Ambient conditions
Degree of protection (EN 60529)
- IP 65
Storage Temperature
- -40C + 80C
Humidity
- ≤ 100 % RH , condensing
Vibration (sinusoidal) (EN 60068-2-6)
- 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
Output signal
Without transmitter
- 1 x Pt100, 3-wire
- 1 x Pt100, 4-wire
- 2 x Pt100, 3-wire
- 1 x Pt1000, 3-wire
- 2 x Pt1000, 3-wire
With transmitter
- 4 … 20 mA , 2-wire Loop Powered
- 4 … 20 mA , 2-wire + HART® Loop Powered
Termination
- Ceramic Terminal Block
- Transmitter
- Free Leads
Optional Housing
- Style Selectable
- Material Selectable
Accessories
- Nipple Union Nipple Standard 60mm
- Nipple 10mm…40mm
- Threaded Lag ½”BSP or NPT length configurable
- Tri-Clover Lag ½”….4” length configurable
Compliance and approvals
EMC
- EN 61326-1
Process Thread
- ½” BSP or NPT
- ¾” BSP or NPT
- 1”BSP or NPT
Instrument Thread
- ½”BSP
- ½”NPT
Insertion length
- 20 … 3000 mm
Well tube Diameter
- Standard 11mm diameter 7mm internal diameter
- 12mm diameter 9mm internal diameter
- Customisable upon request
Well tube material
- AISI 316L (1.4404)
Surface roughness wetted parts
- Ra ≤ 0.8 µm
Performance characteristics
Max. flow velocity
- See Datasheet
Thermal response time
- See datasheet
Certification Options
- See 3.1b Material Cert
- Surface Finish Cert