This sensor assembly is generally used within the dairy, brewery & pharmaceutical industry where a sanitary process connection is required. It consists of a Pt100 sensing element housed in a stainless steel protective sheath with a floating nut which locks upon a measured collar & a lag/standoff. These assemblies are generally of a high surface finish as required for such processes. The termination head which can be Aluminium, Plastic or Stainless Steel.
Performance Characteristics
- Max. Flow Velocity- 40 m/s , gases
- 5 m/s , liquids
 
- Process Pressure- ≤ 25 bar
 
- Pt100 accuracy class (EN 60751)- A (± 0.15 °C at 0 °C)
- ± (0.15 + 0.002 × t)°C
- 1/3 B (± 0.1 °C at 0 °C)
- ± 1/3 × (0.3 + 0.005 × t)°C
- 1/10 B (± 0.03 °C at 0 °C)
- ± 1/10 × (0.3 + 0.005 × t)°C
 
- Pt1000 accuracy class (EN 60751)- A (± 0.15 °C at 0 °C)
- ± (0.15 + 0.002 × t)°C
- 1/3 B (± 0.1 °C at 0 °C)
- ± 1/3 × (0.3 + 0.005 × t)°C
 
- Thermal Response Time, T50- ≤ 7.6 s , Ø8 mm
 
- Operating Temperature- Standard -70°C + 250°C
- High Temperature 600°C
- Cryo -196°C + 250°C
 
- Sensor Length- 80 mm
 
- Sensor Diameter- 8 mm
 
- Sensor Tube Material- AISI 316L (1.4404)
- Surface Roughness Wetted Parts Ra ≤ 0.8 µm
 
- Ambient Conditions- Degree of Protection (EN 60529)- IP 67
 
 
- Degree of Protection (EN 60529)
- Storage Temperature Range- -40°C … 85°C
 
- Humidity- ≤ 100 % RH , condensing
 
- Vibration (sinusoidal) (EN 60068-2-6)- 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
 
- Output Signal- Without Transmitter- 1 x Pt100, 3-wire
- 1 x Pt100, 4-wire
- 2 x Pt100, 3-wire
- 1 x Pt1000, 3-wire
- 2 x Pt1000, 3-wire
 
- With Transmitter- 4 … 20 mA , 2-wire
- 4 … 20 mA , 2-wire + HART®
 
 
- Without Transmitter
- Compliance and Approvals- EMC- EN 61326-1
 
 
- EMC
- Housing- Style Selectable
- Material Selectable
- Process Thread Floating Nut ¾”BSP
 